ModulSystem Schröders
Hinged doors and gates for your security
Fire resistance, smoke control, bullet resistance, burglar resistance, acoustic performance, internal area, external area
| Hinged doors and gates | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Hinged security doors, security gates | Fire resistance | Smoke control | Bullet resistance | Burglar resistance | Acoustic performance |
Airtightness
wind load watertightness |
Positive and negative pressure | |||||||||||
| Type | Leaves | Dimensions
width x height (mm) |
Flat | Resistance class | Designation | Class | Resistance class | Insulation values | Class | |||||||||
| EIS-1/60 | 1 |
|
✔ | EI2 60 E 120 EW 60 (120 min. tested) |
Sa4 / S200 | - | - | - | airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
| EIS-2/60 | 2 |
|
✔ | EI2 60 E 120 EW 60 (120 min. tested) |
Sa4 / S200 | - | - | - | airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
| EIS-11 | 1 |
|
✔ | EI2120-Sa4-C5 | S200 | - | RC2, RC1 | - | airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
| TSN-1 CE | 1 |
|
✔ | EI230-Sa4-C5 | S200 | up to FB6 | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 53 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
| TSN-2 CE | 2 |
|
✔ | EI230-Sa4-C5 | S200 | up to FB6 | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 48 (-1;-5) dB |
airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
| TSN-3 CE | 1 |
|
✔ | EI260-Sa4-C5 | S200 | - | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 53 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
| TSN-4 CE | 2 |
|
✔ | EI260-Sa4-C5 | S200 | - | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 48 (-1;-5) dB |
airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
| TSN-11 CE | 1 |
|
✔ | EI290-Sa4-C5 | S200 | - | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 53 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
| TSN-12 CE | 2 |
|
✔ | EI290-Sa4-C5 | S200 | - | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 48 (-1;-5) dB |
airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
| ES-1/60 | 1 |
|
✔ | E 60
EW 60 |
- | - | - | - | - | up to 5,000 Pa | ||||||||
| ES-2/60 | 2 |
|
✔ | E 60
EW 60 |
- | - | - | - | - | up to 3,800 Pa | ||||||||
| ES-1/120 | 1 |
|
✔ | E 120
EW 60 |
- | - | - | - | - | up to 5,000 Pa | ||||||||
| ES-2/120 | 2 |
|
✔ | E 120
EW 60 |
- | - | - | - | - | up to 3,800 Pa | ||||||||
| ES-1/180 | 1 |
|
✔ | E 180
EW 60 |
- | - | - | - | - | up to 5,000 Pa | ||||||||
| ES-2/180 | 2 |
|
✔ | E 180
EW 60 |
- | - | - | - | - | up to 3,800 Pa | ||||||||
| ES-1/240 | 1 |
|
✔ | E 240
EW 60 |
- | - | - | - | - | up to 5,000 Pa | ||||||||
| ES-2/240 | 2 |
|
✔ | E 240
EW 60 |
- | - | - | - | - | up to 3,800 Pa | ||||||||
| RSN-1 CE | 1 |
|
✔ | - | S200-C5 | up to FB6 | RC4, RC3, RC2, RC1 |
up to
RW(C;Ctr) = 53 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
| RSN-2 CE | 2 |
|
✔ | - | S200-C5 | up to FB6 | RC4, RC3, RC2, RC1 |
up to
RW(C;Ctr) = 48 (-1;-5) dB |
airtight up to 3
wind up to C4 rain up to 3A |
up to
3,800 Pa |
||||||||
| FBN-1 | 1 |
|
✔ | - | - | up to FB6 | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 51 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
| FBN-2 | 1 |
|
✔ | - | - | up to FB6 | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 46 (-1;-5) dB |
airtight up to 3
wind up to C5 rain up to 4A |
up to 3,800 Pa | ||||||||
| ESN-1 | 1 |
|
✔ | - | - | - | up to RC4 | up to
RW(C;Ctr) = 53 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
| ESN-2 | 2 |
|
✔ | - | - | - | up to RC4 | up to
RW(C;Ctr) = 48 (-1;-5) dB |
airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
| SN-1 | 1 |
|
✔ | - | - | - | - | up to
RW(C;Ctr) = 53 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
| SN-2 | 2 |
|
✔ | - | - | - | - | up to
RW(C;Ctr) = 48 (-1;-5) dB |
airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
| ASN-1 | 1 | depending on performance characteristic | ✔ | - | - | - | - | - | airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
| ASN-2 | 2 | depending on performance characteristic | ✔ | - | - | - | - | - | airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
| ISN-1 | 1 | depending on performance characteristic | ✔ | - | - | - | - | - | airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
| ISN-2 | 2 | depending on performance characteristic | ✔ | - | - | - | - | - | airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
| Hinged steel fire doors British standard | ||||||||||||||||||
| Tested according to BS 476, part 22 | Fire-resistance | tested at:
|
||||||||||||||||
| Designation | Leaves | Dimensions
width x height |
Flat | Resistance | Certificate | optional
glazing |
optional
stainless steel |
|||||||||||
| BSN-1/60 | 1 |
|
- | 60 minutes | WFRC No. C103480 | yes | yes | |||||||||||
| BSN-2/60 | 2 |
|
- | 60 minutes | WFRC No. C103484 | yes | yes | |||||||||||
| BSN-1/120 | 1 |
|
- | 120 minutes | WFRC No. C103481 | yes | yes | |||||||||||
| BSN-2/120 | 2 |
|
- | 120 minutes | WFRC No. C103485 | yes | yes | |||||||||||
| BSN-1/180 | 1 |
|
- | 180 minutes | WFRC No. C103482 | yes | yes | |||||||||||
| BSN-2/180 | 2 |
|
- | 180 minutes | WFRC No. C103486 | - | yes | |||||||||||
| BSN-1/240 | 1 |
|
- | 240 minutes | WFRC No. C103483 | - | yes | |||||||||||
| BSN-2/240 | 2 |
|
- | 240 minutes | WFRC No. 102034 | - | yes | |||||||||||
Explanation of the chart
|
||||||||||||||||||