Smoke control door according to European standard
| System Schröders RSN-2 CE | |
|---|---|
Double-leaf smoke control steel door or gate S200-C5 according to EN 16304 |
|
|
|
|
| Smoke control |
S200 tested according to EN 1634-3
|
| Thermal transmittance |
UD-value ≥ 1.2 W/(m²K) according to EN ISO 10077-1 |
Combinable with additional performance characteristics: |
|
|
Bullet resistance
(optional) |
class FB6 - test report S-25-0202-02/B, Beschussamt Ulm |
| Burglar resistance
(optional) |
RC4 - expert report No. 22-7/15.125, PIV-Velbert
according to DIN EN 1627 ff |
| Acoustic performance
(optional) |
up to RW (C;Ctr) = 48 (-1;-5) dB according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717 |
|
Airtightness
(optional) |
up to class 3 according to EN 12207 (± 600 Pa) expert report No. 40-40/12.122, PIV Velbert |
| Resistance to wind load
(optional) |
up to class C4 according to EN 12210 (± 1.600 Pa) expert report No. 40-40/12.122, PIV Velbert |
| Watertightness
(optional) |
up to class 4A according to EN 12208 (± 150 Pa) expert report No. 40-40/12.122, PIV Velbert |
| Resistance to positive and negative pressure
(optional) |
according to DIN EN 12211 (up to 3,800 Pa) expert report No. 40-52/16.120 |
| Behavior between different climates
(optional) |
class 2 (d + e) according to EN 12219 (deflection) |
| Ability to release
(optional) |
according to DIN EN 16034
according to DIN EN 14351-1 |
| Flush with surface
(optional) |
|
| Explosion protection
(optional) |
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for hinged doors System Schröders (in German language) (PDF)
|
Performance characteristics are combinable with further door types „System Schröders“: |
|
| Fire resistance
(optional) |
EI290-S200 (Fire door System Schröders TSN-12 CE) tested according to EN 1634-1 |
| Technical description | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Dimensions
(rough building dimension) |
|
|||||||||
| Door leaf |
leaf thickness 68 mm to 69 mm - smooth double-walled
securing pins |
|||||||||
| Frame | frame-system "ZNG"
or "ZG"
with elastic rubber seal corner frame
|
|||||||||
| Floor seal |
lowerable floor seal RSI
|
|||||||||
| Glazing
(optional) |
glass dimensions and -form variable minimum frieze width: 130 mm
glass inset bars with concealed screw connection (for rectangular glazing) |
|||||||||
| Hinges |
2/3-part KO door hinges per leaf
|
|||||||||
| Fittings |
for RC version: ES-1 to ES-3 security fittings |
|||||||||
| Locking |
active leaf
single locking according to EN 12209, depending on version multi-point locking
internal snap bolt (locking upwards)
|
|||||||||
| Self closing |
both leafs with door closer according to DIN EN 1154 |
|||||||||
| Installation |
|
|||||||||
| Label |
|
|||||||||
| Optional |
|
|||||||||
|
The information provided relates to standard equipment variants. When combining different performance characteristics, customised equipment may be required. The licensed System Schröders manufacturers will be happy to consult you on planning your requirements. |
||||||||||
For installation in potentially explosive areas, please see confirmation letter