Burglar resistance door
| System Schröders ESN-1 | |
|---|---|
Single-leaf burglar resistance steel door or flap |
|
| Burglar resistance |
RC4 - expert report No. 22-5/15.125, PIV-Velbert
according to DIN EN 1627 - 1630 |
Combinable with additional performance characteristics: |
|
| Thermal transmittance
(optional) |
UD-value ≥ 1.3 W/(m²K) according to EN ISO 10077-1 |
| Acoustic performance
(optional) |
up to RW (C;Ctr) = 53 (-1;-5) dB according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717 |
| Arc fault protection
(optional) |
pressure resistance exceeding 30,000 Pa according to DIN / EN / IEC 62271-202-2022, Section 7.102 and Annex A |
| Installation in external walls
(optional) |
according to DIN EN 14351-1 |
| Airtightness
(optional) |
up to class 4 according to EN 12207 (± 600 Pa) expert report 40-14/26, PIV Velbert |
| Resistance to wind load
(optional) |
up to class C5 according to EN 12210 (± 2.000 Pa) expert report 40-14/26, PIV Velbert |
| Watertightness
(optional) |
up to class 8A according to EN 12208 (+ 450 Pa) expert report 40-14/26, PIV Velbert |
| Resistance to positive and negative pressure
(optional) |
according to DIN EN 12211 (up to 5,000 Pa) expert report No. 16-003037-PR01 |
| Behavior between different climates
(optional) |
class 2 (d + e) according to EN 12219 (deflection) |
| Ability to release
(optional) |
according to DIN EN 14351-1 |
| Flush with surface
(optional) |
|
| Explosion protection
(optional) |
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for hinged doors System Schröders (in German language) (PDF)
|
| Potential equalisation
(optional) |
according to DIN EN 50310, DIN VDE 0100-410 resp. DIN VDE 0100-540 |
| Water splash and poke protection
(optional) |
up to IP44 according to DIN EN 60529 |
Performance characteristics are combinable with further door types „System Schröders“: |
|
| Fire resistance
(optional) |
EI290-Sa4 (Fire door System Schröders TSN-11 CE) tested according to EN 1634-1 |
| Smoke control
(optional) |
S200 (smoke control door System Schröders RSN-1 CE) tested according to EN 1634-3 RS (smoke control door System Schröders RSN-1) nach DIN 18095 |
| Bullet resistance
(optional) |
up to class FB6 (e.g. bullet resistance door FBN-1) tested according to EN 1522/1523 beim Beschussamt Ulm |
| Technical description | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Dimensions
(standard building dimensions) |
|
||||||||||||||||
| Top panel |
|
||||||||||||||||
| Door leaf |
leaf thickness 68 mm to 69 mm - smooth double-walled
securing pins |
||||||||||||||||
| Frame | frame-system "ZNG"
or "ZG"
seal depending on performance characteristics
corner frame
|
||||||||||||||||
| Rebate protection (from RC3) |
rebate protection by ESP safety profile (patent-protected) |
||||||||||||||||
| Floor seal |
depending on performance characteristics
|
||||||||||||||||
| Glazing
(optional) |
glass dimensions and -form variable minimum frieze width: 100 mm
glass inset bars with concealed screw connection (for rectangular glazing) |
||||||||||||||||
|
Ventilation (optional) |
gill ventilation, louvre ventilation, bar grille | ||||||||||||||||
| Hinges |
2/3-part KO door hinges
|
||||||||||||||||
| Fittings |
|
||||||||||||||||
| Locking |
|
||||||||||||||||
|
Self closing
(optional) |
door closer according to DIN EN 1154 |
||||||||||||||||
| Installation |
|
||||||||||||||||
| Optional |
|
||||||||||||||||
|
The information provided relates to standard equipment variants. When combining different performance characteristics, customised equipment may be required. The licensed System Schröders manufacturers will be happy to consult you on planning your requirements. |
|||||||||||||||||
For installation in potentially explosive areas, please see confirmation letter