open the System Schröders - door
Technical drawing  FBN-1

Bullet resistance door

System Schröders FBN-1

Single-leaf bullet resistance door according to EN 1522/1523

Bullet resistance

class FB6 - test report S-23-0208-04/05, Beschussamt Ulm
class FB4 - test report S-23-0208-01/02, Beschussamt Ulm

tested according to EN 1522/1523

Combinable with additional performance characteristics:

Thermal transmittance
(optional)

UD-value ≥ 1.3 W/(m²K) according to EN ISO 10077-1

Burglar resistance
(optional)

RC4 - expert report No. 22-5/15.125, PIV-Velbert
RC3 - expert report No. 22-4/15.125, PIV-Velbert
RC2 - expert report No. 45-47/22.126, PIV-Velbert
RC1 - expert report No. 45-47/22.126, PIV-Velbert

according to DIN EN 1627 - 1630

Acoustic performance
(optional)

up to RW (C;Ctr) = 51 (-1;-5) dB

according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717

Installation in external walls
(optional)

according to DIN EN 14351-1 CE-Zeichen labelled

Airtightness
(optional)

up to class 4 according to EN 12207 (± 600 Pa)

expert report 40-14/26, PIV Velbert
Resistance to wind load
(optional)

up to class C5 according to EN 12210 (± 2.000 Pa)

expert report 40-14/26, PIV Velbert
Watertightness
(optional)

up to class 8A according to EN 12208 (+ 450 Pa)

expert report 40-14/26, PIV Velbert
Resistance to positive and negative pressure
(optional)

according to DIN EN 12211 (up to 5,000 Pa)

expert report No. 16-003037-PR01
Behavior between different climates
(optional)

class 2 (d + e) according to EN 12219 (deflection)

Ability to release
(optional)

according to DIN EN 14351-1
proven for doors in escape and rescue routes

Flush with surface
(optional)

flush-mounted design FLAT

Explosion protection
(optional)
Logo ATEX For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for hinged doors System Schröders (in German language) (PDF)

Performance characteristics are combinable with further door types „System Schröders“:

Fire resistance
(optional)

EI230-Sa4 (fire door System Schröders TSN-1 CE)

tested according to EN 1634-1

Smoke control
(optional)

S200 (smoke control door System Schröders RSN-1 CE)

tested according to EN 1634-3

Technical description
Dimensions
(standard building dimensions)
width from 500 mm to 1,625 mm
heigth from 500 mm to 3,250 mm


door leaf maximum 3 m² (600 kg)

limitations on additional performance characteristics possible
e.g. burglar resistance, acoustic performance, Airtightness and/or water tightness


deviating special sizes possible, subject to individual confirmation
Door leaf

leaf thickness 69 mm - smooth double-walled
plate thickness 1.5 mm

  • thin rebate
    • optional thick rebate

securing pins

Frame frame-system "ZNG"

seal depending on performance characteristics

  • elastic rubber seal
  • silicone seal

corner frame

  • optional enclosing frame
  • optional block frame
Threshold
  • optional with bullet-resistant threshold

Doors without a bullet-resistant threshold always represent a safety risk, as a projectile can pass through the lower door gap.

Floor seal

depending on performance characteristics

  • without seal
  • lowerable floor seal
  • stop seal
  • sliding seal / grinding seal
Glazing
(optional)
  • FB4: bullet resistant rectangular glazing according to EN 1063 BR4-NS

glazing dimensions variable

minimum frieze width: 130 mm

glass inset bars with concealed screw connection

Hinges

2/3-part KO door hinges
with patented easy-running bearings as Easy-running doors
or with ball-Bearing spacer rings

  • optional door hinge with 3D adjustment

SLB heavy-duty hinges for door leaves from 400 kg

Fittings

ES3 fittings

  • optional visor fitting with 5-point locking system
Locking

various locking systems possible

profile cylinder prepared (cylinder on-site)

Self closing
(optional)

door closer according to DIN EN 1154

Installation

proven with mortared corner frame / attachment frame

  • in statically suitable, bullet-resistant walls according to the corresponding bullet resistance class
Optional
  • additional security devices possible
    (magnetic contact, bolt contact, e-opener...)
  • stainless steel design
  • bullet resistant door viewer up to FB6

The information provided relates to standard equipment variants. When combining different performance characteristics, customised equipment may be required.

The licensed System Schröders manufacturers will be happy to consult you on planning your requirements.