open the System Schröders - door
Technical drawing  ASN-2

Multi purpose external door

System Schröders ASN-2

Double-leaf multi purpose external steel door according to DIN EN 14351-1

CE-Zeichen labelled

Thermal transmittance

UD-value ≥ 1.2 W/(m²K) according to EN ISO 10077-1

Combinable with additional performance characteristics:

Arc fault protection
(optional)
pressure resistance exceeding 30,000 Pa
according to DIN / EN / IEC 62271-202-2022, Section 7.102 and Annex A
Airtightness
(optional)

up to class 3 according to EN 12207 (± 600 Pa)

expert report No. 40-40/12.122, PIV Velbert
Resistance to wind load
(optional)

up to class C5 according to EN 12210 (± 2.000 Pa)

expert report No. 40-40/12.122, PIV Velbert
Watertightness
(optional)

up to class 4A according to EN 12208 (± 150 Pa)

expert report No. 40-40/12.122, PIV Velbert
Resistance to positive and negative pressure
(optional)

according to DIN EN 12211 (up to 3,800 Pa)

expert report No. 40-52/16.120
Behavior between different climates
(optional)

class 2 (d + e) according to EN 12219 (deflection)

Ability to release
(optional)

according to DIN EN 14351-1
proven for doors in escape and rescue routes

Flush with surface
(optional)

flush-mounted design FLAT

Explosion protection
(optional)
Logo ATEX For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for hinged doors System Schröders (in German language) (PDF)
Potential equalisation
(optional)

according to DIN EN 50310, DIN VDE 0100-410 resp. DIN VDE 0100-540

Water splash and poke protection
(optional)

up to IP44 according to DIN EN 60529
test report 44-1/26 PIV Velbert

Performance characteristics are combinable with further door types „System Schröders“:

Fire resistance
(optional)

EI290-Sa4 (Fire door System Schröders TSN-12 CE)
EI260-Sa4 (Fire door System Schröders TSN-4 CE)
EI230-Sa4 (Fire door System Schröders TSN-2 CE)

tested according to EN 1634-1

Smoke control
(optional)

S200 (smoke control door System Schröders RSN-2 CE)

tested according to EN 1634-3

Bullet resistance
(optional)

up to class FB6 (e.g. bullet resistance door FBN-2)

tested according to EN 1522/1523 beim Beschussamt Ulm

Burglar resistance
(optional)

up to RC4 (e.g. burglar resistance door System Schröders ESN-2)

according to DIN EN 1627 ff

Acoustic performance
(optional)

up to RW (C;Ctr) = 48 (-1;-5) dB (e.g. acoustic performance door System Schröders SN-2)

according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717

Technical description
Dimensions
(standard building dimensions)

no specifications
limitations on additional performance characteristics possible

Top panel
  • optional with fixed skylight / top panel
Side panel
  • optional with fixed side panel / side panels
Door leaf

leaf thickness 68 mm to 69 mm - smooth double-walled
plate thickness 1.0 mm to 1.5 mm

  • thin rebate
    • optional thick rebate

securing pins

Frame frame-system "ZNG" or "ZG"

seal depending on performance characteristics

  • elastic rubber seal
  • silicone seal

corner frame

  • optional enclosing frame
  • optional block frame
Floor seal

depending on performance characteristics

  • without seal
  • lowerable floor seal
  • stop seal
  • sliding seal / grinding seal
Glazing
(optional)

glass dimensions and -form variable

minimum frieze width: 90 mm

  • optional with intermediate glass inset bars
  • optional with port-hole
  • optional in top panel

glass inset bars with concealed screw connection (for rectangular glazing)

Ventilation
(optional)
gill ventilation, louvre ventilation, bar grille
Hinges

2/3-part KO door hinges per leaf
with patented easy-running bearings as Easy-running doors
or with ball-Bearing spacer rings

  • optional door hinge with 3D adjustment
Fittings

various fittings possible

Locking

various locking systems possible

active leaf

profile cylinder prepared (cylinder on-site)

Self closing
(optional)

both leafs with door closer according to DIN EN 1154
with door closing sequence control according to EN1158

Installation
  • in masonry
  • in concrete
  • in aerated concrete
  • in mounting walls
  • in timber stud walls
  • in steel frames / steel containers
  • in facing walls
  • optional blunt installation in soffit
  • optional installation on the wall plate
Label

according to DIN EN 14351-1 CE-Zeichen labelled

Optional
  • additional security devices possible
    (magnetic contact, bolt contact, e-opener...)
  • stainless steel design

The information provided relates to standard equipment variants. When combining different performance characteristics, customised equipment may be required.

The licensed System Schröders manufacturers will be happy to consult you on planning your requirements.