open the System Schröders - door

ModulSystem Schröders

Hinged external doors and external gates
ModulSystem Schröders Fire resistance Smoke control Bullet resistance Burglar resistance Acoustic performance Airtightness
wind load
watertightness
Positive and negative pressure
Type Leaves Dimensions
width x height (mm)
Flat Resistance class Designation Class Resistance class Insulation values Class  
ASN-1 1 depending on performance characteristic ✔ - - - - - airtight up to 4
wind up to C5
rain up to 8A
up to 5,000 Pa
ASN-2 2 depending on performance characteristic ✔ - - - - - airtight up to 3
wind up to C4
rain up to 3A
up to 3,800 Pa
further door and gate types "System Schröders"that can be equipped as external doors
ModulSystem Schröders Fire resistance Smoke control Bullet resistance Burglar resistance Acoustic performance Airtightness
wind load
watertightness
Positive and negative pressure
Type Leaves Dimensions
width x height (mm)
Flat Resistance class Designation Class Resistance class Insulation values Class  
TSN-1 CE 1
from 525  x  500
to 2,300  x  4,600
✔ EI230-Sa4-C5 S200 up to FB6 RC4, RC3, RC2, RC1 up to
RW(C;Ctr)
= 53 (-1;-5) dB
airtight up to 4
wind up to C5
rain up to 8A
up to 5,000 Pa
TSN-2 CE 2
from 1,250  x  1,900
to 4,600  x  4,600
✔ EI230-Sa4-C5 S200 up to FB6 RC4, RC3, RC2, RC1 up to
RW(C;Ctr)
= 48 (-1;-5) dB
airtight up to 3
wind up to C4
rain up to 3A
up to 3,800 Pa
TSN-3 CE 1
from 525  x  750
to 1,750  x  3,500
✔ EI260-Sa4-C5 S200 - RC4, RC3, RC2, RC1 up to
RW(C;Ctr)
= 53 (-1;-5) dB
airtight up to 4
wind up to C5
rain up to 8A
up to 5,000 Pa
TSN-4 CE 2
from 1,375  x  1,750
to 3,500  x  3,500
✔ EI260-Sa4-C5 S200 - RC4, RC3, RC2, RC1 up to
RW(C;Ctr)
= 48 (-1;-5) dB
airtight up to 3
wind up to C4
rain up to 3A
up to 3,800 Pa
TSN-11 CE 1
from 525  x  750
to 1,500  x  2,950
✔ EI290-Sa4-C5 S200 - RC4, RC3, RC2, RC1 up to
RW(C;Ctr)
= 53 (-1;-5) dB
airtight up to 4
wind up to C5
rain up to 8A
up to 5,000 Pa
TSN-12 CE 2
from 1,375  x  1,750
to 3,250  x  3,250
✔ EI290-Sa4-C5 S200 - RC4, RC3, RC2, RC1 up to
RW(C;Ctr)
= 48 (-1;-5) dB
airtight up to 3
wind up to C4
rain up to 3A
up to 3,800 Pa
EIS-11 1
from 500  x  750
to 1,400  x  2,650
✔ EI2120-Sa4-C5 S200 - RC2, RC1 - airtight up to 4
wind up to C5
rain up to 8A
up to 5,000 Pa
RSN-1 CE 1
from 525  x  500
to 2,025  x  4,050
✔ - S200-C5 up to FB6 RC4, RC3, RC2, RC1 up to
RW(C;Ctr)
= 53 (-1;-5) dB
airtight up to 4
wind up to C5
rain up to 8A
up to 5,000 Pa
RSN-2 CE 2
from 1,250  x  1,900
to 4,050  x  4,050
✔ - S200-C5 up to FB6 RC4, RC3, RC2, RC1 up to
RW(C;Ctr)
= 48 (-1;-5) dB
airtight up to 3
wind up to C4
rain up to 3A
up to
3,800 Pa
FBN-1 1
up to 3 m³
✔ - - up to FB6 RC4, RC3, RC2, RC1 up to
RW(C;Ctr)
= 51 (-1;-5) dB
airtight up to 4
wind up to C5
rain up to 8A
up to 5,000 Pa
FBN-2 1
up to 3 m³ per leaf
✔ - - up to FB6 RC4, RC3, RC2, RC1 up to
RW(C;Ctr)
= 46 (-1;-5) dB
airtight up to 3
wind up to C5
rain up to 4A
up to 3,800 Pa
ESN-1 1
from 500 x 500
to 1,625 x 3,250
✔ - - - up to RC4 up to
RW(C;Ctr)
= 53 (-1;-5) dB
airtight up to 4
wind up to C5
rain up to 8A
up to 5,000 Pa
ESN-2 2
from 1,000 x 500
to 3,250 x 3,250
✔ - - - up to RC4 up to
RW(C;Ctr)
= 48 (-1;-5) dB
airtight up to 3
wind up to C4
rain up to 3A
up to 3,800 Pa
SN-1 1
from 600 x 600
to 1,400 x 3,050
✔ - - - - up to
RW(C;Ctr)
= 53 (-1;-5) dB
airtight up to 4
wind up to C5
rain up to 8A
up to 5,000 Pa
SN-2 2
from 1,250 x 1,250
to 3,450 x 3,450
✔ - - - - up to
RW(C;Ctr)
= 48 (-1;-5) dB
airtight up to 3
wind up to C4
rain up to 3A
up to 3,800 Pa

Explanation of the chart

  • The chart shows possible combinations of different performance requirements.
  • The standard performance requirement for each door type is shown in bold. The other performance requirements listed can be added to the relevant door type if required.
  • Please click on the relevant door type to view the detailed product descriptions.
  • Approvals, test certificates, technical drawings, tender documents and product brochures can be found under the relevant door type.
  • The range of dimensions may vary when combining different performance requirements.