Multi purpose ceiling access hatch
| System Schröders DKN-1 | |
|---|---|
Single-leaf internal or external multipurpose ceiling steel flap |
|
|
|
|
|
Installation in internal ceilings
(optional) |
according to DIN ENV 14351-2 |
|
Installation in external ceilings
(optional) |
according to DIN EN 14351-1 |
Combinable with additional performance characteristics: |
|
| Burglar resistance (optional) |
RC4 - expert report No. 22-5/15.125, PIV-Velbert
according to DIN EN 1627 ff |
| Acoustic performance
(optional) |
Bis RW (C;Ctr) = 42 (-1;-3) dB*
(Fire resistant ceiling access hatch T90 System Schröders THF) measurement report81 16 48 52 29 -10, TÜV Nord
*Due to the permissible measurement range of the ceiling access hatch, the maximum sound insulation value of RW RW (C;Ctr) = 45 (-1;-3) dB stated in the test report |
| Thermal transmittance
(optional) |
UD-value ≥ 1.3 W/(m²K) according to EN ISO 10077-1 |
| Airtightness
(optional) |
up to class 4 according to EN 12207 (± 600 Pa) expert report 40-14/26, PIV Velbert |
| Resistance to wind load
(optional) |
up to class C5 according to EN 12210 (± 2.000 Pa) expert report 40-14/26, PIV Velbert |
| Resistance to positive and negative pressure
(optional) |
according to DIN EN 12211 (up to 5,000 Pa)
expert report No. 16-003037-PR01 |
| Explosion protection
(optional) |
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for hinged doors System Schröders (in German language) (PDF)
|
Performance characteristics combinable with further ceiling access hatches „System Schröders“: |
|
| Fire resistance |
(Fire resistant ceiling access hatch T90 System Schröders THF) |
| Smoke control |
tested according to DIN 18095 RS-1
(Fire resistant ceiling access hatch T90 System Schröders THF) |
| Technical description | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dimensions
(rough building dimension) |
|
||||||||||||
| Flap leaf |
leaf thickness 68 mm to 69 mm - smooth double-walled
|
||||||||||||
| Frame | frame-system "ZNG"
or "ZG"
seal depending on performance characteristics
corner frame
|
||||||||||||
| Hinges |
concealed door hinges
no concealed hinges for burglar resistance with top attack side |
||||||||||||
| Fittings |
top side: embedded folding ring shell for burglar resistance with top-mounted lever handle ES1 on the attack side |
||||||||||||
| Locking |
single locking
|
||||||||||||
| Walkability
(optional) |
|
||||||||||||
| Opening assist |
gas strut
|
||||||||||||
| Installation |
|
||||||||||||
| Label |
|
||||||||||||
| Optional |
|
||||||||||||
|
The information provided relates to standard equipment variants. When combining different performance characteristics, customised equipment may be required. The licensed System Schröders manufacturers will be happy to consult you on planning your requirements. |
|||||||||||||
For installation in potentially explosive areas, please see confirmation letter