ModulSystem Schröders
Doors and gates for your security
Fire resistance, smoke control, bullet resistance, burglar resistance, acoustic performance, internal area, external area
Schröders ModulSystem door chart PDF-file
| Hinged doors and gates | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ModulSystem Schröders | Fire resistance | Smoke control | Bullet resistance | Burglar resistance | Acoustic performance |
Airtightness
wind load watertightness |
Positive and negative pressure | |||||||||||
| Type | Leaves | Dimensions
width x height (mm) |
Flat | Resistance class | Designation | Class | Resistance class | Insulation values | Class | |||||||||
|
TSN-1 CE fire door acc. to EN 16034 CE-labelled |
1 |
|
✔ | EI230-Sa4-C5 | S200 | up to FB6 | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 53 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
|
TSN-2 CE fire door acc. to EN 16034 CE-labelled |
2 |
|
✔ | EI230-Sa4-C5 | S200 | up to FB6 | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 48 (-1;-5) dB |
airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
|
TSN-3 CE fire door acc. to EN 16034 CE-labelled |
1 |
|
✔ | EI260-Sa4-C5 | S200 | - | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 53 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
|
TSN-4 CE fire door acc. to EN 16034 CE-labelled |
2 |
|
✔ | EI260-Sa4-C5 | S200 | - | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 48 (-1;-5) dB |
airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
|
TSN-11 CE fire door acc. to EN 16034 CE-labelled |
1 |
|
✔ | EI290-Sa4-C5 | S200 | - | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 53 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
|
TSN-12 CE fire door acc. to EN 16034 CE-labelled |
2 |
|
✔ | EI290-Sa4-C5 | S200 | - | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 48 (-1;-5) dB |
airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
|
EIS-1/60 fire door acc. to EN 16034 CE-labelled |
1 |
|
✔ | EI2 60 E 120 EW 60 (120 min. tested) |
Sa4 / S200 | - | - | - | airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
|
EIS-2/60 fire door acc. to EN 16034 CE-labelled |
2 |
|
✔ | EI2 60 E 120 EW 60 (120 min. tested) |
Sa4 / S200 | - | - | - | airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
|
EIS-11 fire door acc. to EN 16034 CE-labelled |
1 |
|
✔ | EI2120-Sa4-C5 | S200 | - | RC2, RC1 | - | airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
|
ES-1/60 fire door acc. to EN 16034 CE-labelled |
1 |
|
✔ | E 60
EW 60 |
- | - | - | - | - | up to 5,000 Pa | ||||||||
|
ES-2/60 fire door acc. to EN 16034 CE-labelled |
2 |
|
✔ | E 60
EW 60 |
- | - | - | - | - | up to 3,800 Pa | ||||||||
|
ES-1/120 fire door acc. to EN 16034 CE-labelled |
1 |
|
✔ | E 120
EW 60 |
- | - | - | - | - | up to 5,000 Pa | ||||||||
|
ES-2/120 fire door acc. to EN 16034 CE-labelled |
2 |
|
✔ | E 120
EW 60 |
- | - | - | - | - | up to 3,800 Pa | ||||||||
|
ES-1/180 fire door acc. to EN 16034 CE-labelled |
1 |
|
✔ | E 180
EW 60 |
- | - | - | - | - | up to 5,000 Pa | ||||||||
|
ES-2/180 fire door acc. to EN 16034 CE-labelled |
2 |
|
✔ | E 180
EW 60 |
- | - | - | - | - | up to 3,800 Pa | ||||||||
|
ES-1/240 fire door acc. to EN 16034 CE-labelled |
1 |
|
✔ | E 240
EW 60 |
- | - | - | - | - | up to 5,000 Pa | ||||||||
|
ES-2/240 fire door acc. to EN 16034 CE-labelled |
2 |
|
✔ | E 240
EW 60 |
- | - | - | - | - | up to 3,800 Pa | ||||||||
|
RSN-1 CE smoke control door acc. to EN 16034 CE-labelled |
1 |
|
✔ | - | S200-C5 | up to FB6 | RC4, RC3, RC2, RC1 |
up to
RW(C;Ctr) = 53 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
|
RSN-2 CE smoke control door acc. to EN 16034 CE-labelled |
2 |
|
✔ | - | S200-C5 | up to FB6 | RC4, RC3, RC2, RC1 |
up to
RW(C;Ctr) = 48 (-1;-5) dB |
airtight up to 3
wind up to C4 rain up to 3A |
up to
3,800 Pa |
||||||||
|
FBN-1 bullet resistance door |
1 |
|
✔ | - | - | up to FB6 | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 51 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
|
FBN-2 bullet resistance door |
1 |
|
✔ | - | - | up to FB6 | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 46 (-1;-5) dB |
airtight up to 3
wind up to C5 rain up to 4A |
up to 3,800 Pa | ||||||||
|
ESN-1 burglar resistance door |
1 |
|
✔ | - | - | - | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 53 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
|
ESN-2 burglar resistance door |
2 |
|
✔ | - | - | - | RC4, RC3, RC2, RC1 | up to
RW(C;Ctr) = 48 (-1;-5) dB |
airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
|
SN-1 acoustic performance door |
1 |
|
✔ | - | - | - | - | up to
RW(C;Ctr) = 53 (-1;-5) dB |
airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
|
SN-2 acoustic performance door |
2 |
|
✔ | - | - | - | - | up to
RW(C;Ctr) = 48 (-1;-5) dB |
airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
|
ASN-1 external door |
1 | depending on performance characteristic | ✔ | - | - | - | - | - | airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
|
ASN-2 external door |
2 | depending on performance characteristic | ✔ | - | - | - | - | - | airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
|
ISN-1 internal door |
1 | depending on performance characteristic | ✔ | - | - | - | - | - | airtight up to 4
wind up to C5 rain up to 8A |
up to 5,000 Pa | ||||||||
|
ISN-2 internal door |
2 | depending on performance characteristic | ✔ | - | - | - | - | - | airtight up to 3
wind up to C4 rain up to 3A |
up to 3,800 Pa | ||||||||
|
THF fire ceiling flap |
1 |
|
- | T-90 | RS | - | - | up to
RW(C;Ctr) = 42 (-1;-3) dB |
airtight up to 4
wind up to C5 |
up to 5,000 Pa | ||||||||
|
DKN-1 multi purpose ceiling flap |
1 | depending on performance characteristic | - | - | - | - | RC4, RC3, RC2, RC1 |
up to
RW(C;Ctr) = 45 (-1;-3) dB |
airtight up to 4
wind up to C5 |
up to 5,000 Pa | ||||||||
|
DKN-2 multi purpose ceiling flap |
2 | depending on performance characteristic | - | - | - | - | RC4, RC3, RC2, RC1 |
up to
RW(C;Ctr) = 45 (-0;-3) dB |
airtight up to 4
wind up to C5 |
up to 3,800 Pa | ||||||||
| Hinged steel fire doors British standard | ||||||||||||||||||
| Tested according to BS 476, part 22 | Fire-resistance | tested at:
|
||||||||||||||||
| Designation | Leaves | Dimensions
width x height |
Flat | Resistance | Certificate | optional
glazing |
optional
stainless steel |
|||||||||||
|
BSN-1/60 fire door acc. to BS 476 |
1 |
|
- | 60 minutes | WFRC No. C103480 | yes | yes | |||||||||||
|
BSN-2/60 fire door acc. to BS 476 |
2 |
|
- | 60 minutes | WFRC No. C103484 | yes | yes | |||||||||||
|
BSN-1/120 fire door acc. to BS 476 |
1 |
|
- | 120 minutes | WFRC No. C103481 | yes | yes | |||||||||||
|
BSN-2/120 fire door acc. to BS 476 |
2 |
|
- | 120 minutes | WFRC No. C103485 | yes | yes | |||||||||||
|
BSN-1/180 fire door acc. to BS 476 |
1 |
|
- | 180 minutes | WFRC No. C103482 | yes | yes | |||||||||||
|
BSN-2/180 fire door acc. to BS 476 |
2 |
|
- | 180 minutes | WFRC No. C103486 | - | yes | |||||||||||
|
BSN-1/240 fire door acc. to BS 476 |
1 |
|
- | 240 minutes | WFRC No. C103483 | - | yes | |||||||||||
|
BSN-2/240 fire door acc. to BS 476 |
2 |
|
- | 240 minutes | WFRC No. 102034 | - | yes | |||||||||||
Explanation of the chart
|
||||||||||||||||||