Deutsche Flagge Englische Flagge Französische Flagge Türkische Flagge open the System Schröders - door
technical drawing EIS-1

Fire resistance door class EI

System Schröders EIS-1

Single-leaf fire resistance door EI2 60 / E 120 / EW 60 (120) (Sa/S200)

Fire resistance EI2 60 / E 120 / EW 60 (120 tested)
tested in accordance with EN 1634-1
classification report WFRC 302467 according to EN 13501-2
Smoke control
(optional)
(Sa/S200) tested according to EN 1634-3
classification report WFRC 302467 according to EN 13501-2  
Thermal transmittance
(optional)

UD-Wert ≥ 2.8 W/(m²K) according to EN ISO 10077-1

Airtightness
(optional)
according to EN 12207, up to class 4
Resistance to wind load
(optional)
according to EN 12210, up to class C5
Watertightness
(optional)
according to EN 12208, up to class 8A
Ability to release
(optional)
 
Resistance to positive and negative pressure
(optional)
up to 5,000 Pa
Technical data
Dimensions
Standard dimensions
width from 625 mm to 1,500 mm
heigth from 1,725 mm to 3,000 mm
Door leaf Leaf thickness 68 / 69 mm - smooth, double-walled, galvanized or optional stainless steel
plate thickness up to 1.5 mm
  • insulation inlay optional covered with a fully adhering cover sheet, to result in a super smooth and flat door leaf
  • "Thelesol110" fire protection strip on the door leaf edges
Door frame Door frames „System Schröders“
(see installation variants)

optional with elastic smoke control seal
corner frame profile, three, or optional four sided wraparound frame option
  • door leaf and frame optional in stainless steel
Glazing
(optional)
Glass dimensions variable, max. 942 x 2,155 mm
minimum frieze width: 130 mm
  • optional cross bars
Floor seal Required for smoke control, increased air tightness, driving rain tightness
  • optional lowering floor seal or
  • four­sided frame seal
Lock options Latch lock according to EN 12209
profile cylinder prefab (cylinder on-site)
  • optional panic lock
  • optional multiple interock
securing holt
Hardware / fittings
  • Optional any appropriate lever handle set
  • optional panic push-bar

door closer according to EN 1154

2/3-part KO door hinges
with patented easy-running bearings as easy running doors
or with ball bearing rings

optional hinge with 3D adjustability

for smaller doors, optional with spring hinge

  • optional power drive door opener according to EN 1155
Installation
- in masonry
- in concrete
- in fire proof mounting walls, at least F60
- ­in steel columns or beams covered, at least F60
  • optional blunt mount between the recesses
Options
  • ­additional safety equipment possible
    (magnetic contact, bolt contact, electric door opener)
  • with door closers
  • thick rebate design (development in progress)
  • stainless steel
  • protective kick plates ≤ 1.5 mm on the door panel
  • door panel covered with laminates or genuine wood veneer ≤ 1.5 mm
  • additional versions upon request