Fire resistance door class E
| System Schröders ES-2 | |
|---|---|
Double-leaf fire door ES-2/240 |
|
| Fire resistance period | 240 minutes |
| Fire resistance test
in accordance with |
EN 1634-1 (European standard) |
| Tested at | Warrington Fire Research, Warrington / UK |
| Certificate | WFRC 343498 |
| Resistance to positive and negative pressure
(optional) |
up to 5,000 Pa |
| Options |
|
| Technical data | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Dimensions |
|
|||||||||
| Doorleaf | single-acting leaf of mild steel,
galvanized / stainless steel steel sheets bonded with core material for extremely smooth surface doorleaf weight ~ 20 kg/m² debated doorleaf - thickness: 68 mm steel sheet - thickness: 0.8 - 1.6 mm |
|||||||||
| Optional Glazing | clear dimensions variable to a maximum of 800 mm x 800 mm
- rectangular glazing - circular glazing ∅ 450 mm (clear dimension) |
|||||||||
| Hardware | solid mortise latch and lock
dogbolt on hingeside 2 hinges |
|||||||||
| Self-closing | doorcloser EN 1154 Dorma TS83 Code IMM
1 spring hinge as standard for rebated door |
|||||||||
| Handles | heavy cast-iron handles with plates or other handles / plates
assemblies admitted for mounting on fire doors |
|||||||||
| Antipanic-system | door leaf can be equipped with antipanic lock and antipanic bar | |||||||||
| Frame | steel doorframe
1.5 - 3 mm galvanized or stainless steel with steel reinforcements for hinges and doorcloser |
|||||||||