Deutsche Flagge Englische Flagge Französische Flagge Türkische Flagge open the System Schröders - door
Technische Zeichnung ESN-2

Burglar resistance door

System Schröders ESN-2

Double-leaf burglar resistance steel door

Burglar resistance

RC4 - classification report no. 22-7/15.123, PIV-Velbert
RC3 - classification report no. 22-6/15.123, PIV-Velbert
RC2 - classification report no. 45-48/22.122, PIV-Velbert
RC1 - classification report no. 45-48/22.122, PIV-Velbert

according to DIN EN 1627 ff

Thermal transmittance

UD-Wert ≥ 1.2 W/(m²K) according to EN ISO 10077-1

Behaviour between different climates according to EN 12219 (deflection) class 2 (d + e)
Acoustic performance
(optional)
up to RW (C;Ctr) = 48 (-1;-5) dB*
according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717-1
* depending on size, see expert assessment 820SST298-Hrd - TÜV Nord (de)
 
Airtightness
(optional)
according to EN 12207, up to class 3
Resistance to wind load
(optional)
according to EN 12210, up to class C4
Watertightness
(optional)
according to EN 12208, up to class 3A
Ability to release
(optional)
 
Resistance to positive and negative pressure
(optional)
up to 3,800 Pa
Installation in outer walls
(optional)
CE-Zeichen marked according to EN 14351-1
 
Technical data
Dimensions
standard dimensions
width from 1.050 mm to 3.250 mm
heigth from 1,750 mm to 3,000 mm
 
Door leaf leaf thickness 68 / 70 mm - smooth, double-walled
plate thickness 1.5 mm to 2.0 mm
mineral wool filling (other fillings on request)
 
Door frame door frame "ZNG"
  • elastic rubber seal (optonal)
corner frame
  • optional closed frame
Glazing
(optional)
glass dimensions variable
minimum frieze width: 130 mm
  • optional cross bars
RC4: glazing according to EN356 min. P6B
RC3: glazing according to EN356 min. P5A
Glazing beads with concealed screws
Floor seal
  • optional retractable floor seal or patented sliding seal
Lock options
Active leaf
RC4: three-point lock
 
  • (optional NEMEF, BMH, HZ-Lock, Fliether, Dorma, eff eff)
  • Securing pins
  • for panic lock with full-surface drilling protection
     
RC3: simple locking with single-latch bolt lock min. DIN 18251 class 3
 
  • optional panic lock (not with glazing)
  from door height > 2,500 mm
  three-point lock
 
  • (optional NEMEF, BMH, HZ-Lock, Fliether, Dorma, effeff)
  • Securing pins
     
Fixed leaf
RC3 / RC4:
  • shoot bolt with locking up and down
  • dogbolts
     
rebate protection rebate protection through ESP safety profile (patent-protected).
 
Hardware / fittings
  • optional any appropriate lever handle set
  • optional panic push-bar
  • version RC4: Protective fitting 18257 ES3
  • version RC3: Protective fitting 18257 ES2
  • version RC1 or RC2: Protective fitting 18257 ES1

both leaves with door closer according to EN 1154 und door coordinator device

both leaves with 2/3 ­piece KO ­door hinges
with patented easy-running bearings as easy running doors
or with ball bearing spacers

optional hinge with 3D adjustability

Installation
  • in masonry
  • in concrete
  • in aereated concrete
  • in steel frame
  • optional blunt mount
Options ­additional safety equipment possible
  • (­magnetic contact, bolt contact, electric door opener)
  • with door closers
thick rebate design
stainless steel finish
further version on request