Deutsche Flagge Englische Flagge Französische Flagge Türkische Flagge open the System Schröders - door
Technische Zeichnung ESN-2

Burglar resistance door

System Schröders ESN-2

Double-leaf burglar resistance steel door

Burglar resistance Burglar resistance door according to EN 1627
RC4 - classification report 22-18/04 ERW, PIV Velbert, Germany
RC3 - classification report 22-17/04 ERW, PIV Velbert, Germany
RC2 - classification report 212 24303, ift Rosenheim, Germany
RC1 - classification report 212 24302, ift Rosenheim, Germany
 
Acoustic performance
(optional)
up to RW (C;Ctr) = 42 (-1;-4) dB* according to EN 20140-3
classification report 162 26873/4.1.0, ift Rosenheim, Germany

up to RW (C;Ctr) = 39 (-1;-2) dB* according to EN 20140-3
classification report 162 26873/4.4.0, ift Rosenheim, Germany

up to RW (C;Ctr) = 37 (-1;-2) dB* according to EN 20140-3
classification report 162 26873/4.0.0, ift Rosenheim, Germany


*depending on size see expert opinion 175 31584/1, ift Rosenheim, Germany
 
Thermal transmittance according to EN ISO 10077-1, UD-value ≥ 1,9
Airtightness
(optional)
according to EN 12207, up to class 3
Resistance to wind load
(optional)
according to EN 12210, up to class C4
Watertightness
(optional)
according to EN 12208, up to class 3A
Ability to release
(optional)
 
Resistance to positive and negative pressure
(optional)
up to 3,800 Pa
Installation in outer walls
(optional)
CE-Zeichen marked according to EN 14351-1
 

Technical data

Dimensions
Standard dimensions
width from 1.050 mm to 3.250 mm
heigth from 1,750 mm to 3,000 mm
 
Door leaf Leaf thickness 68 / 70 mm - smooth, double-walled
plate thickness 1.5 mm to 2.0 mm
Mineralwollfüllung (andere Füllungen auf Anfrage)
 
Door frame Door frame "ZNG"
  • elastic rubber seal (optonal)
corner frame
  • optional closed frame
Glazing
(optional)
Glass dimensions variable
minimum frieze width: 130 mm
  • optional cross bars
RC4: Glazing according to EN356 min. P6B
RC3: Glazing according to EN356 min. P5A
Glazing beads with concealed screws
Floor seal
  • optional retractable floor seal or patented sliding seal
Lock options
Active leaf
RC4: Three-point lock
 
  • (optional NEMEF, BMH, HZ-Lock, Fliether, Dorma, eff eff)
  • Securing pins
  • for panic lock with full-surface drilling protection
     
RC3: simple locking with single-latch bolt lock min. DIN 18 251 class 3
 
  • optional panic lock (not with glazing)
  from door height > 2,500 mm
  Three-point lock
 
  • (optional NEMEF, BMH, HZ-Lock, Fliether, Dorma, effeff)
  • Securing pins
     
Fixed leaf
RC3 / RC4:
  • Shoot bolt with locking up and down
  • Securing pins
     
rebate protection Rebate protection through ESP safety profile (patent-protected).
 
Hardware / fittings
  • optional any appropriate lever handle set
  • optional panic push-bar
  • bei Ausführung RC4: Schutzbeschlag 18257 ES3
  • bei Ausführung RC3: Schutzbeschlag 18257 ES2
  • bei Ausführung RC1 oder RC2: Schutzbeschlag 18257 ES1

both leaves with door closer according to EN 1154 und door coordinator device

both leaves with 2/3 ­piece KO ­door hinges
with patented easy-running bearings as easy running doors
or with ball bearing spacers

optional hinge with 3D adjustability

Installation
  • in masonry
  • in concrete
  • in aereated concrete
  • in steel frame
  • optional blunt mount
Options ­additional safety equipment possible
  • (­magnetic contact, bolt contact, electric door opener)
  • with door closers
thick rebate design
stainless steel finish
further version on request